Service Specifications

GENERATOR SERVICE SPECIFICATIONS

Application Specification
Rated Output 12 Volts/80 Amps
Rotor Coil resistance @ 68°F (20°C) 2.1-2.5 Ohms
Slip Ring Diameter
Standard .559-.567 in. (14.2-14.4 mm)
Minimum .504 in. (12.8 mm)
Brush Exposed Length
Standard .374-.453 in. (9.5-11.5 mm)
Minimum .059 in. (1.5 mm)
CHARGING SYSTEM SERVICE DATA (VOLTAGE REGULATOR)

Application Specification
Regulating Voltage 13.2-14 Volts