Inspection Procedure
- INSPECT MULTIPLEX NETWORK SWITCH ASSEMBLY
- Remove the switch.
- Measure the resistance of the switch when the switch is operated.
Resistance
MULTIPLEX NETWORK SWITCH ASSEMBLYSwitch Condition Tester Connection Specified Condition AUTO UP 1 (D) - 7 (E) 6 (U) - 12 (BW) Below 1Ω UP 1 (D) - 7 (E) 6 (U) - 12 (BW) Below 1Ω OFF 1 (D) - 7 (E) 6 (U) - 7 (E) Below 1Ω DOWN 6 (U) - 7 (E) 1 (D) - 12 (BW) Below 1Ω AUTO DOWN 6 (U) - 7 (E) 1 (D) - 12 (BW) Below 1Ω
NG: REPLACE MULTIPLEX NETWORK SWITCH ASSEMBLY
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE