Freeze Frame Data
- FREEZE FRAME DATA NOTE:
- It is difficult to show specified values (judgment values) clearly because freeze frame data values change significantly due to differences in measurement conditions, surroundings, or vehicle conditions. For this reason, there may be a problem even when the values are within specifications.
- Turn the ignition switch to ON and park the vehicle on level ground. Check the freeze frame data by using the Techstream.
- Turn the ignition switch off.
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Enter the following menus: Chassis / EMPS / Trouble Codes. Check the freeze frame data by following the prompts on the Techstream.
EMPS
FREEZE FRAME DATATester Display Item Description: Range (Display) Inspection Condition Reference Value Meter Vehicle Velocity Vehicle speed from meter/
Min.: 0 km/h (0 mph)
Max.: 300 km/h (186.4 mph)Vehicle is stopped 0 km/h (0 mph) Vehicle is driven at a constant speed No significant fluctuation Engine Revolution Engine revolution/
Min.: 0 rpm
Max.: 12800 rpmEngine is running at a constant speed No significant fluctuation Motor Actual Current Amount of current to motor/
Min.:-327.68 A
Max.: 327.67 APower steering is operating Value changes in proportion to steering effort Command Value Current Demanded amount of current to motor/
Min.:-327.68 A
Max.: 327.67 APower steering is operating Value changes in proportion to steering effort Steering Angle Velocity Steering angle speed/
Min.: -327.68 deg/s
Max.: 327.67 deg/sSteering wheel is turned Value changes in proportion to steering effort Thermistor Temperature ECU substrate temperature/
Min.: -40°C (-40°F)
Max.: 150°C (302°F)Ignition switch ON - PIG Power Supply Power source voltage to activate motor/
Min.: 0 V
Max.: 20.1531 VPower steering is operating 9 to 16 V IG Power Supply ECU power source voltage/
Min.: 0 V
Max.: 20.1531 VIgnition switch ON 9 to 16 V Motor Rotation Angle Motor rotation angle/
Min.: 0 deg
Max.: 1441.77 degPower steering is operating During steering operation, motor rotation angle value changes from 0 to 360° Command Val Current 2 Demanded amount of current to motor/
Min.:-327.68 A
Max.: 327.67 APower steering is operating Value changes in proportion to steering effort PIG2 Voltage Voltage after boosting by coil/
Min.: 0 V
Max.: 45.955 VIgnition switch ON
Steering wheel is not turnedApproximately 27 V Ignition switch ON
Steering wheel is turnedValue changes within 4 to 35 V range Motor Voltage Motor power supply voltage/
Min.: 0V
Max.: 45.955 VIgnition switch ON
Steering wheel is not turnedApproximately 27 V Ignition switch ON
Steering wheel is turnedValue changes within 4 to 35 V range Motor Terminal Volt (U) Motor terminal voltage (U phase)/
Min.: 0 V
Max.: 46.667 VSteering wheel is turned Value changes within 4 to 35 V range Motor Terminal Volt (V) Motor terminal voltage (V phase)/
Min.: 0 V
Max.: 46.667 VSteering wheel is turned Value changes within 4 to 35 V range Motor Terminal Volt (W) Motor terminal voltage (W phase)/
Min.: 0 V
Max.: 46.667 VSteering wheel is turned Value changes within 4 to 35 V range Torque Sensor 1 Output Torque sensor voltage/
Min.: 0V
Max.: 5 VIgnition switch ON
Steering wheel is not turned (without load)2.3 to 2.7 V Ignition switch ON
Steering wheel is turned to right with vehicle stopped2.5 to 3.8 V Ignition switch ON
Steering wheel is turned to left with vehicle stopped1.2 to 2.5 V Torque Sensor 2 Output Torque sensor voltage/
Min.: 0V
Max.: 5 VIgnition switch ON
Steering wheel is not turned (without load)2.3 to 2.7 V Ignition switch ON
Steering wheel is turned to right with vehicle stopped1.2 to 2.5 V Ignition switch ON
Steering wheel is turned to left with vehicle stopped2.5 to 3.8 V TRQ1 Zero Point Value Torque sensor voltage/
Min.: 0V
Max.: 5 VSteering wheel is not turned - TRQ2 Zero Point Value Torque sensor voltage/
Min.: 0 V
Max.: 5 VSteering wheel is not turned - PS Assist Signal Power steering assist signal/ ON or OFF No steering load (in neutral position) OFF Ignition switch ON
Steering wheel is turnedON