Vehicle Stability Control System: Calibration
- CLEAR ZERO POINT CALIBRATION (WHEN USING TECHSTREAM):
- Connect Techstream to the DLC3.
- Turn the ignition switch to the ON position.
- Operate Techstream to erase the codes (select "Reset Memory").
HINT:
Refer to the Techstream operator's manual for further details.
- Using Techstream, perform zero point calibration of the yaw rate and deceleration sensor.
- PERFORM ZERO POINT CALIBRATION OF YAW RATE AND DECELERATION SENSOR (WHEN USING TECHSTREAM): NOTE:
- While obtaining the zero point, do not vibrate the vehicle by tilting, moving or shaking it and keep it in a stationary condition. (Do not turn the ignition switch to the ON position.)
- Be sure to do this on a level surface (with an inclination of less than 1 %).
- Procedures for test mode.
- Check that the steering wheel is in the straight-ahead position and move the shift lever to the P position and apply the parking brake.
- Connect Techstream to the DLC3.
- Turn the ignition switch to the ON position.
- Set Techstream to test mode (select "Test Mode").
HINT:
Refer to the Techstream operator's manual for further details.
- Obtain the zero point of the yaw rate and deceleration sensor.
- Keep the vehicle in the stationary condition on a level surface for 2 seconds or more.
- Check that the ABS warning light and VSC warning light blink.
HINT:
- If the ABS warning light and VSC warning light do not blink perform zero point calibration again.
- The zero point calibration is performed only once after the system enters the test mode.
- Calibration cannot be performed again until the stored data is cleared once.
- Turn the ignition switch off and disconnect Techstream.
- PERFORM ZERO POINT CALIBRATION OF YAW RATE AND DECELERATION SENSOR (WHEN USING SST CHECK WIRE): NOTE:
- While obtaining the zero point, do not vibrate the vehicle by tilting, moving or shaking it and keep it in a stationary condition. (Do not turn the ignition switch to the ON position.)
- Be sure to do this on a level surface (with an inclination of less than 1 %).
- Clear the zero point calibration.
- Turn the ignition switch to the ON position.
- Using SST, connect and disconnect terminals TS and CG of the DLC3 4 times or more within 8 seconds.
SST 09843-18040
- Procedures for test mode.
- Turn the ignition switch off.
- Using SST, connect terminals TS and CG of the DLC3.
SST 09843-18040
- Check that the steering wheel is in the straight-ahead position and move the shift lever to the P position.
- Obtain the zero point of the yaw rate and deceleration sensor.
- Turn the ignition switch to the ON position.
- Keep the vehicle in a stationary condition on a level surface for 2 seconds or more.
- Check that the ABS warning light and VSC light blink (test mode).
HINT:
- If the ABS warning light and VSC warning light do not blink perform zero point calibration again.
- The zero point calibration is performed only once after the system enters the test mode.
- Calibration cannot be performed again until the stored data is cleared once.
- Turn the ignition switch off and disconnect the SST from the DLC3.