Typical Malfunction Thresholds

CASE 1

The following condition is met 2 data or more
One of the following conditions (a), (b) or (c) is met More then 3 times
(a) EEPROM access error Occurred
(b) Permanent Fault Code Not stored
(c) Permanent Fault Code Not equal to commanded Fault Code
CASE 2

The following condition is met 2 data or more
Either of the following conditions (a) or (b) is met More then 3 times
(a) EEPROM access error Occurred
(b) Permanent Fault Code Stored
2. Clearing processing is more than 10 seconds Not completed
CASE 3

Either of the following conditions is met 1 or 2
1. The following condition is met 2 data or more
EEPROM access error (more than 3 times) Occurred
2. Permanent Fault Code data (more than 10 times) Mismatch