DTC P0D56-15: Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open [09/2016 - ]: Description
Refer to the description for DTC P0D56-11.
Refer to DESCRIPTION
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0D56-15 | Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open | PISW terminal voltage remains more than 4.73 V for a certain period of time. (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |