DTC P1CE9-31: Charger Cooling Fan Revolution Sensor No Signal; DTC P1CE9-96: Charger Cooling Fan Revolution Sensor Component Internal Failure [09/2016 - ]: Description
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P1CE9-31 | Charger Cooling Fan Revolution Sensor No Signal | The insufficient rotation counter is more than the judgment value. (1 trip detection logic) |
|
Does not come on | Master Warning Light: Comes on |
| P1CE9-96 | Charger Cooling Fan Revolution Sensor Component Internal Failure | The cooling fan speed is lower than the threshold for 10 seconds or more. (1 trip detection logic) |
|
Does not come on | Master Warning Light: Comes on |
RELATED DATA LIST
| DTC No. | Data List |
|---|---|
| P1CE9-31 |
|