Restraints Occupant Classification System Module Communication Stop Mode [11/2015 - ]: Procedure
- CHECK FOR OPEN IN CAN BUS LINES (OCCUPANT DETECTION ECU BRANCH LINE)
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the a8 occupant detection ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
(a8)
(a8)
Tester Connection Condition Specified Condition a8-5 (CANH) - a8-4 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω Result
Result OK NG
Result:
NG
REPAIR OR REPLACE CAN BRANCH LINES OR CONNECTOR (OCCUPANT DETECTION ECU)
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
(a8)
(a8)
Tester Connection Condition Specified Condition a8-10 (GND) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω - Reconnect the cable to the negative (-) auxiliary battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
(a8)
(a8)
Tester Connection Condition Specified Condition a8-6 (IG2) - Body ground Power switch on (IG) 11 to 14 V Result
Result OK NG
Result:
OK
REPLACE OCCUPANT DETECTION ECU. Refer to REMOVAL [11/2015 - 12/2018] , or refer to REMOVAL [12/2018 - 07/2020] , or refer to REMOVAL [07/2020 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.