Typical Malfunction Thresholds

CASE 1

Either of the following conditions 1 or 2 is met 2 data or more
1. One of the following conditions (a), (b) or (c) is met More then 3 times
(a) EEPROM communication timeout Occurred
(b) Permanent Fault Code Not stored
(c) Permanent Fault Code Not equal to commanded Fault Code
2. Storing processing is more than 10 seconds Not completed
CASE 2

Either of the following conditions 1 or 2 is met 2 data or more
1. Either of the following conditions (a) or (b) is met More then 3 times
(a) EEPROM communication timeout Occurred
(b) Permanent Fault Code Stored
2. Clearing processing is more than 10 seconds Not completed
CASE 3

Either of the following conditions is met 1 or 2
1. Either of the following conditions (a) or (b) is met 2 data or more
(a) EEPROM communication timeout (3 times) Occurred
(b) Reading processing is more than 10 seconds Not completed
2. Permanent Fault Code data (10 times) Mismatch