Operating Conditions
| Enable Criteria | LIN2 fully functional Normal supply voltage 9V-16 V |
| Failure Criteria | LIN signal ERR_ST_INTL_00_SZL=0x1:Error Active or ERR_ST_INTL_01_SZL=0x1:Error Active or ERR_ST_INTL_02_SZL=0x1:Error Active or ERR_ST_INTL_03_SZL=0x1:Error Active or ERR_ST_INTL_04_SZL=0x1:Error Active or ERR_ST_DRS_00_SZL=0x1:Error Active or ERR_ST_DRS_01_SZL=0x1:Error Active or ERR_ST_DRS_02_SZL=0x1:Error Active or ERR_ST_SWS_00_SZL=0x1:Error Active or ERR_ST_SWS_01_SZL=0x1:Error Active or ERR_ST_KRL_00_SZL=0x1:Error Active or ERR_ST_KRL_01_SZL =0x1:Error Active or ERR_ST_AIC_00_SZL=0x1:Error Active or ERR_ST_DIM_SZL =0x1:Error active or NOD_ERR_SZL_LIN =0x1:Error active |
| Failure/Mature Time | Continuous receive four times |
| Pass Criteria | ERR_ST_INTL_00_SZL = 0x0 "No Error" and ERR_ST_INTL_01_SZL = 0x0 "No Error" and ERR_ST_INTL_02_SZL = 0x0 "No Error" and ERR_ST_INTL_03_SZL =0x0 "No Error" and ERR_ST_INTL_04_SZL =0x0 "No Error" and ERR_ST_DRS_00_SZL = 0x0 "No Error" and ERR_ST_DRS_01_SZL =0x0 "No Error" and ERR_ST_DRS_02_SZL =0x0 "No Error" and ERR_ST_SWS_00_SZL = 0x0 "No Error" and ERR_ST_SWS_01_SZL = 0x0 "No Error" and ERR_ST_KRL_00_SZL = 0x0 "No Error" and ERR_ST_KRL_01_SZL = 0x0 "No Error" and ERR_ST_AIC_00_SZL = 0x0 "No Error" and ERR_ST_DIM_SZL = 0x0 "No Error" and NOD_ERR_SZL_LIN =0 "No Error" |
| Pass/De-mature Time | Continuous receive four times |
| Failure Aging | 40 Ignition cycles |