Operating Conditions
| Enable Criteria |
|
| Failure Criteria | ANY ONE of the following rolling count signals does not behave according to CAN specification: CPD_OUTPUT (0x307).ALV_CPD_Output_1 CPD_WarnMsg (0x4AF).ALV_CPD_WarnMsg |
| Failure/Mature Time | Immediate |
| Pass Criteria | ALL of the following rolling count signals behave according to CAN specification: CPD_OUTPUT (0x307).ALV_CPD_Output_1 CPD_WarnMsg (0x4AF).ALV_CPD_WarnMsg |
| Pass/De-mature Time | Immediate |
| Failure Aging | 100 Ignition Cycles |