Operating Conditions
| Enable Criteria | ECU On IGN On The Battery voltage is between 9V to 16V. |
| Failure Criteria | Wrong alive counter (not by one sequentially) is received continuously. Signal name: ALV_SAS_Sensor |
| Failure/Mature Time | 100 ms |
| Pass Criteria | Message is received normally over 100 ms |
| Pass/De-mature Time | 100 ms |
| Failure Aging | 40 Ignition cycles. |