Home >> VinFast >> 2023 >> VF8 Eco >> Repair and Diagnosis (Single Page) >> Hybrid/Electric Powertrain >> Electric Motor Systems >> Front/Rear Drive Motor Control Diagnosis (2 Of 2) >> DTC U3000-98: Control Module - Inverter Or Motor Over Temperature - Component Or System Over Temperature >> VinFast DTC Guided Repair Instruction >> Operating Conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Operating Conditions

Enable Criteria Ignition ON
Failure Criteria In three-phase IGBT DBC temperature, as long as the difference of absolute value between any two-phase temperature > 15 Celsius
In case of desaturation, overcurrent and other phenomena in 1edi2002as lower bridge, fault mark position 1 or 1edi2002as lower bridge monitors its own power supply (its own clock, watchdog). When power supply (its own clock, watchdog) is abnormal, fault mark position 1 is considered as fault.
In the ASC state, when the inverter temperature and sensor DBC temperature exceeds the temperature threshold
CAL_MDF_tThd_TempDBCInvSens3Pha_f32 (102°C) or the coolant temperature exceeds the temperature threshold
CAL_MDF_tThd_TempDBCInvCoolObsvr_f32 (75°C), or the stator temperature exceeds the temperature threshold _tfd_MDF_Str (180°C), It is considered that a short circuit over temperature fault has occurred. And this fault is not available in this power-on cycle restore
Failure/Mature Time 110 ms
Pass Criteria in three-phase IGBT DBC temperature, the difference of absolute value between all two-phase temperature < 15 Celsius
When power supply is normal, the fault mark position is 0.
In Active short-circuit state, when the DBC temperature value, or the inverter temperature sensor less than the temperature threshold (102°C), the watercooling temperature less than the temperature threshold (75°C), the stator temperature less than the temperature threshold (180°C)
Pass/De-mature Time 110 ms
Failure Aging 40 Ignition cycles.