Work sequence
- Connect Scan Tool (ST) VAG 1551.
- Press buttons - 0 - and - 1 - to insert "Engine Electronics" address word 01. Engine must be running at idle (connecting scan tool and selecting engine electronics control module → Scan Tool (ST) VAG 1551 , connecting and selecting functions ).
Indicated on display
| Rapid data transfer HELP Select function XX |
- Press buttons - 0 - and - 8 - to select "Read Measuring Value Block" function 08.
Indicated on display
| Read Measuring Value Block Input display group number XXX |
- Select required display group number.
NOTE:
- The display group number 0 is used as an example to illustrate the sequence.
- Press buttons - 0 - , - 0 - and - 0 - to input display group number 00 - 000 - and press - Q - button to confirm input.
Indicated on display (1-10 = display fields)
| Read Measuring Value Block 0 -> 1 2 3 4 5 6 7 8 9 10 |
NOTE:
- To change to another display group proceed as follows:
| Display group | Scan Tool (ST) VAG 1551 | Scan Tool (ST) VAG 1552 |
| Higher | Press button - 3 - | Press ↑ button |
| Lower | Press button - 1 - | Press ↓ button |
| Skip | Press button - C - | Press button - C - |
- If specifications in all display fields are obtained, press → button.
- If one of the specifications is not obtained.
Additional measures → repair procedures.
Indicated on display
| Rapid data transfer HELP Select function XX |
- Press buttons - 0 - and - 6 - to select "End output" function 06 and press - Q - button to confirm input.
- Switch ignition off.