Display group 10 - Ignition
| Display group 10 - Ignition | ||||||
|
||||||
| Read measured value block 10 | → | Indicated on display | ||||
| xxxx rpm | xxx.x % | xxx.x % | xx.x ° BTDC | |||
| 1 | 2 | 3 | 4 | Display zones | Specification | Evaluation |
| Ignition timing angle | 4.0...15.0 ° BTDC | --- | ||||
| Throttle valve angle Angle sensor -1- for throttle drive G187 | 0.2...4.0 % | Evaluating display group 10, display zone 3 - Throttle valve angle, Angle sensor - 1 - for throttle drive | ||||
| Engine load | 12.0...26.0 % | Evaluating display group 10, display zone 2 - Engine load | ||||
| Engine speed (idle speed) | 640...720 rpm | Evaluating display group 1, display zone 1 - Engine speed (idle speed) | ||||
NOTE:
- Note on display zone 2:
- The engine load at idling is given as the specification.
NOTE:
- Note on display zone 3:
- Display values must be approx. 100 % when accelerator pedal is fully depressed.