Test conditions
- All fuses must be OK.
- Ignition on, engine not running
NOTE:
- The Output Diagnostic Test Mode can only be carried out if the engine is stationary and ignition switched on.
- The Output Diagnostic Test Mode will be broken off if the engine is started or a rotational impulse is recognized.
- During the Output Diagnostic Test Mode the individual final controls will be activated until advancing to the next final control by pressing the → button.
- The final controls are checked acoustically or by touching.
- If it is necessary to repeat the Output Diagnostic Test Mode, without first running the engine briefly, switch the ignition off for approx. 2 seconds.
- The electric fuel pump will run during the complete Output Diagnostic Test Mode.