Diagnostic mode 2: Checking operating conditions: Procedure
- Connect diagnostic tester, see CONNECT DIAGNOSTIC TESTER .
- Depending on the desired operating condition: switch on ignition
or Start engine and let run at idle.
- Under address word 33, select "Diagnostic mode 2: Check operating conditions."
- Select the desired operating condition "PID XX".
NOTE:
The operating conditions are sorted by the PID (parameter-identifications).
DISPLAY OPERATING CONDITIONS SPECIFICATION
| PID | Display operating conditions |
|---|---|
| 03: | Condition of the fuel system |
| 04: | Calculated load condition value |
| 05: | Cooling fluid temperature |
| 06: | Short time gasoline -air ratio bank 1 |
| 07: | Gasoline-air ratio bank 1 |
| 12: | Engine rotations per minute (RPM) |
| 13: | Vehicle speed |
- End diagnosis and switch ignition off.