Knock sensor, checking: Notes
NOTE:
- The terminal surfaces between knock sensor and cylinder block must be free of corrosion, dirt and grease.
- Knock Sensor (KS) 2 -G66- has a direct 2-pin connector and therefore no terminal for the shielding in the connector.
- It is extremely important to keep to the torque setting of 20 Nm to ensure the knock sensors perform perfectly.
- Only gold-plated terminals may be used when servicing the knock sensor connector terminals.