Test-ID 34 ($22): Catalyst Monitor Bank 2
-- Connect the scan tool.
-- Start the engine and let run at idle speed.
-- Select "Diagnostic Mode 06 - Check Test Results of Components that are not Continuously Monitored ".
Select "Test-ID 34 ($22)".
-- Select the desired "Test-ID".
-- Check specified values at idle.
| Test-ID (TID) (Hex-ID) | DTC | Component or System | Min. | Max. | Additional Information |
|---|---|---|---|---|---|
| 132 ($84) | P0430 | Cat. monitoring, bank 2 oxygen retention capability (normal operation). For additional information, refer to the Bosch Motronic ME 7.1.1 OBD System Strategy. | 4096 | 65535 | Refer to DTC P0430 in the SAE P0XXX DIAGNOSTIC TROUBLE CODES . |
-- If any of components or systems fail to meet the specified values. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY to check for stored DTC's or the corresponding diagnostic repair procedure.
-- Switch the ignition off.
End of Diagnosis