Checking Wiring
-- Using a Multimeter, Check the NOx Sensor Module -J583- / Nox Sensor -G295- electrical harness connector terminals for resistance, Refer to applicable wiring diagram for fuse location and number.
| NOx Sensor Module -J583- / Nox Sensor -G295- electrical harness connector terminals | Measure to: |
|---|---|
| 1 | Fuse, Refer to applicable wiring diagram for fuse location and number. |
| 2 | Ground |
| 5 | Ground |
Specified value: 1.5 Ω Max.
If the specified value was Not obtained:
-- Check the wiring connection for an open circuit, short circuit to Battery positive or Ground
-- Check the wiring connection for damage, corrosion, loose or broken terminals.
-- If necessary, repair the faulty wiring connection and replace any open fuses.
-- Go to Final Procedures
If the specified value was obtained:
-- Replace the NOx Sensor Module -J583-. Refer to the service information for removal and installation procedures.
-- Go to Final Procedures