Test Procedure
-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK
Start diagnosis
Make sure the engine is at room temperature.
-- Disconnect the EGR Motor 2 -V339- /Exhaust Gas Recirculation Position Sensor 2 -G466- connector.
-- Using a Multimeter, Check the EGR Motor 2 -V339- /Exhaust Gas Recirculation Position Sensor 2 -G466- electrical harness connector terminals 1 to 3 for voltage.
Specified value: about 5.0 V
-- Switch the ignition Off.
Continue test according to the following table:
| Value | Cause | Test |
|---|---|---|
| If the specified value was not obtained: | Open or shorted circuit | Checking Wiring |
| If the specified value was obtained: | Check reference signal circuit | Checking Wiring |