Monitor-ID $3D: Tank Vent Valve Function Check
WARNING: This page is about a different variant/trim than selected.
-- Connect the scan tool.
-- Start the engine and run at idle.
-- Select "Diagnostic Mode 06: Check test the results of components that are not continuously monitored".
Select "Monitor-ID $3D".
-- Select the desired "Test-ID".
-- Check specified values at idle.
| Test-ID | DTC | Component or System | Min. | Max. | Additional Information |
|---|---|---|---|---|---|
| $8A | Pass only | Purge flow okay by adaptation factor purge flow | 20.30 % | 100.00 % | Test: Pass only |
| $8C | P0441 | Purge flow monitor valve open | 0.00 mA | 4.200 to 13.86 mA | Refer to DTC P0441 in the DTC table Engine Control Module -- 2015 MY => P0441 |
| $8D | P0441 | Purge flow monitor valve closed | 0.00 mA | 4.500 to 36.41 mA | Refer to DTC P0441 in the DTC table Engine Control Module -- 2015 MY => P0441 |
-- If any of components or systems fail to meet the specified values. Refer to Diagnostic "Mode 03: Interrogating Fault Memory" to check for stored DTC's or the corresponding diagnostic repair procedure DIAGNOSTIC MODE 03 - READ DTC MEMORY .
-- Switch the ignition OFF.