| P0604 |
Internal Control Module Random Access Memory (RAM) Error |
|
- comparison of writing data and reading data
|
- writing data is different from reading one
|
|
|
|
| P0605 |
Internal Control Module Read Only Memory (ROM) Error |
|
- comparison of stored checksum value and calculated checksum
|
- two checksum values are not same
|
|
|
|
| P0613 |
TCM Processor |
- 2nd CPU detects miscalculation
|
- check-calculation of 1st CPU failed
|
- single reset does not cover problem
|
|
|
|
| P0614 |
ECM/TCM Incompatible |
|
- detection of error signal
|
- transmission coding is manual transmission code (0Fh)
OR
- max torque is not same as one in ATCU
|
- CAN bus: ACTIVE
- ECU communication: ACTIVE
- ECU data update: ACTIVE
|
|
|
| P0705 |
Transmission Range Sensor "A" Circuit (PRNDL Input) |
- A, B, C and PA signal check in every shift lever position.
|
- detection of wrong combination of the A, B, C and PA signal
|
- wrong combination for more than 350 ms
|
|
|
|
| P0715 |
Input Turbine/Speed Sensor "A" Circ |
|
- detection of wrong input AD value
|
- voltage < 0.2 volt (AD value < 45) for more than 100 ms
OR
- (AD value > 545) voltage > 3.8 volt for more than 100 ms
|
- input sensor: no failure decision for input sensor no pulse failure
|
|
|
| P0716 |
Input/Turbine Shaft Speed Sensor "A" Circuit Range/Performance |
|
- comparison pulse of input revolution and output revolution
|
- no pulse of input sensor more than 125 ms
|
- engine speed > 400 rpm
- output sensor: ACTIVE
- output speed >= 300 rpm
- input sensor: no during failure detection or after failure decision for input sensor electrical failure
|
|
|
| P0720 |
output Shaft Speed Sensor Circuit |
|
- detection of wrong input AD value
|
- voltage < 0.2 volt (AD value < 45) for more than 100 ms
OR
- (AD value > 545) voltage > 3.8 volt for more than 100 ms
|
- output sensor: no failure decision for output sensor no pulse
|
|
|
| P0721 |
Output Shaft Speed Sensor Circuit Range/Performance |
|
- comparison pulse of input revolution and output revolution
|
- no pulse of output sensor more than 250 ms
|
- engine speed: > 400 rpm
- input sensor: ACTIVE
- calculated output speed by input speed: >= 300 rpm
- main solenoid switch: ON
- gear condition: Engage
- Range: D, S
- Inhibitor switch: no fault
- output sensor: no during failure detection or after failure decision for output sensor electrical failure
- solenoid: no fault (except S2)
- linear solenoid: no fault
|
|
|
| P0725 |
Engine Speed Input Circuit |
|
- detection of error signal
|
|
- CAN bus: ACTIVE
- ECU communication: ACTIVE
- ECU data update: ACTIVE
|
|
|
| P0729 |
Gear 6 Incorrect Ratio |
- Input and output rpm signal check. Separate error memory for each gear.
|
- comparison of indicated slip and actual slip with stored values
|
- 1. ABS (input revolutions - output revolutions x other gear ratio) < (0.04 x other gear ratio x output revolutions) for more than 1 s
- 2. slip differences > (0.20 x current gear ratio x output revolutions) for more than 1 s
|
- engine speed > 400 rpm
- output revolutions > 250 rpm
- shift lever D or S
- brake: OFF
- slip difference of output speed (In case ABS valid) difference < 10%
- revolution sensor, no back up condition
- model oil temperature >= 0° C
- common parameter, common condition (see Footnote: - Transmission Control Module --, 6-SPD, 09G (2011-2015 MY)).
|
|
|
| P0731 |
Gear 1 Incorrect Ratio |
- Input and output rpm signal check. Separate error memory for each gear.
|
- comparison of indicated slip and actual slip with stored values
|
- ABS (input rev - output rev x other gear ratio) < (0.04 x other gear ratio x output rev) for more than 1 s
|
- engine speed > 400 rpm
- output revolutions > 250 rpm
- estimated engine torque > 100 Nm at 1st gear > 80 Nm at 1st EB gear
- shift lever D or S
- brake: OFF
- slip difference of output speed and ABS difference < 10% (in case of ABS failure, this condition isn't activated)
- engaged gear, 1st gear
- revolution sensor, no back up condition
- model oil temperature >= 20°C
- common parameter, common condition (see Footnote: - Transmission Control Module --, 6-SPD, 09G (2011-2015 MY)).
|
|
|
|
|
- detection of slip condition
|
- input revolutions > output revolutions x 1st gear ratio + 400 rpm for more than 3.3 s
|
- engine speed > 400 rpm
- shift lever D or S
- output revolutions <= 500 rpm
- output revolutions which <= 500 rpm calculated from ABS (In case of ABS failure, this condition isn't activated)
- L-up condition: OFF
- input sensor, no back up condition
- output sensor, active or back up by ABS
- model oil temperature >= 0° C
- common parameter, common condition (see Footnote: - Transmission Control Module --, 6-SPD, 09G (2011-2015 MY)).
|
|
- 2 DCY
- cumulative but, in case of changing the shift lever position, counter = 0
|
| P0732 |
Gear 2 Incorrect Ratio |
|
- detection of slip condition
|
- input revolutions > output revolutions x 1st gear ratio + 400 rpm for more than 3.3 s
|
- engine speed > 400 rpm
- shift lever D or S
- output revolutions <= 500 rpm
- output revolutions which <= 500 rpm calculated from ABS (In case of ABS failure, this condition isn't activated)
- L-up condition: OFF
- input sensor, no back up condition
- output sensor, active or back up by ABS
- model oil temperature >= 0° C
- common parameter, common condition (see Footnote: - Transmission Control Module --, 6-SPD, 09G (2011-2015 MY)).
|
|
- 2 DCY
- cumulative but, in case of changing the shift lever position, counter = 0
|
- Input and output rpm signal check. Separate error memory for each gear.
|
- comparison of indicated slip and actual slip with stored values
|
- 1. ABS (input revolutions - output revolutions x other gear ratio) < (0.04 x other gear ratio x output revolutions) for more than 1 s
- 2. slip differences > (0.20 x current gear ratio x output revolutions) for more than 1 s
|
- engine speed > 400 rpm
- output revolutions > 250 rpm
- shift lever D or S
- brake: OFF
- slip difference of output speed (In case ABS valid) difference < 10%
- revolution sensor, no back up condition
- model oil temperature >= 0° C
- common parameter, common condition (see Footnote: - Transmission Control Module --, 6-SPD, 09G (2011-2015 MY)).
|
|
|
| P0733 |
Gear 3 Incorrect Ratio |
- Input and output rpm signal check. Separate error memory for each gear.
|
- comparison of indicated slip and actual slip with stored values
|
- 1. ABS (input revolutions - output revolutions x other gear ratio) < (0.04 x other gear ratio x output revolutions) for more than 1 s
- 2. slip differences > (0.20 x current gear ratio x output revolutions) for more than 1 s
|
- engine speed > 400 rpm
- output revolutions > 250 rpm
- shift lever D or S
- brake: OFF
- slip difference of output speed (In case ABS valid) difference < 10%
- revolution sensor, no back up condition
- model oil temperature >= 0° C
- common parameter, common condition (see Footnote: - Transmission Control Module --, 6-SPD, 09G (2011-2015 MY)).
|
|
|
| P0734 |
Gear 4 Incorrect Ratio |
- Input and output rpm signal check. Separate error memory for each gear.
|
- comparison of indicated slip and actual slip with stored values
|
- 1. ABS (input revolutions - output revolutions x other gear ratio) < (0.04 x other gear ratio x output revolutions) for more than 1 s
- 2. slip differences > (0.20 x current gear ratio x output revolutions) for more than 1 s
|
- engine speed > 400 rpm
- output revolutions > 250 rpm
- shift lever D or S
- brake: OFF
- slip difference of output speed (In case ABS valid) difference < 10%
- revolution sensor, no back up condition
- model oil temperature >= 0° C
- common parameter, common condition (see Footnote: - Transmission Control Module --, 6-SPD, 09G (2011-2015 MY)).
|
|
|
| P0735 |
Gear 5 Incorrect Ratio |
- Input and output rpm signal check. Separate error memory for each gear.
|
- comparison of indicated slip and actual slip with stored values
|
- 1. ABS (input revolutions - output revolutions x other gear ratio) < (0.04 x other gear ratio x output revolutions) for more than 1 s
- 2. slip differences > (0.20 x current gear ratio x output revolutions) for more than 1 s
|
- engine speed > 400 rpm
- output revolutions > 250 rpm
- shift lever D or S
- brake: OFF
- slip difference of output speed (In case ABS valid) difference < 10%
- revolution sensor, no back up condition
- model oil temperature >= 0° C
- common parameter, common condition (see Footnote: - Transmission Control Module --, 6-SPD, 09G (2011-2015 MY)).
|
|
|
| P0743 |
Torque Converter Clutch Circuit Electrical |
- Input AD value check in every Linear solenoid.
|
- detection of wrong input AD value
|
- feedback current > 1333 mA (AD value > 1000) for more than 100 ms
|
|
|
|
- feedback current < 23 mA (AD value < 15) for more than 100 ms
|
|
- Linear solenoid feedback current check
|
- comparison of target current and feedback current
|
- sum of difference of two current > 20000 Ω
|
- linear feedback current is > 23 mA (AD:15) < 1333 mA (AD:1000)
|
|
|
| P0748 |
Pressure Control Solenoid "A" Electrical |
- Input AD value check in every Linear solenoid.
|
- detection of wrong input AD value
|
- feedback current > 1333 mA (AD value > 1000) for more than 100 ms
|
|
|
|
- feedback current < 23 mA (AD value < 15) for more than 100 ms
|
|
- Linear solenoid feedback current check
|
- comparison of target current and feedback current
|
- sum of difference of two current > 20000 Ω
|
- linear feedback current is > 23 mA (AD:15) < 1333 mA (AD:1000)
|
|
|
| P0753 |
Shift Solenoid "A" Electrical |
- Conduction check in ON/OFF solenoid.
|
- Comparison of the signal of solenoid monitor and solenoid driver output
|
- wrong output signal for more than 100 ms
|
|
|
|
| P0798 |
Pressure Control Solenoid "C" Electrical |
- Input AD value check in every Linear solenoid.
|
- detection of wrong input AD value
|
- feedback current > 1333 mA (AD value > 1000) for more than 100 ms
|
|
|
|
- feedback current < 23 mA (AD value < 15) for more than 100 ms
|
|
- Linear solenoid feedback current check
|
- comparison of target current and feedback current
|
- sum of difference of two current > 20000 Ω
|
- linear feedback current is > 23 mA (AD:15) < 1333 mA (AD:1000)
|
|
|
| P0811 |
Excessive Clutch "A" Slippage |
|
- comparison of engine rpm and input rpm
|
- Engine rpm - input rpm > 100 rpm for 2 s
|
- engine speed > 400 rpm
- shift lever D or S
- engine speed < 4000 rpm
- estimated engine torque >= 0 Nm
- revolution sensor, no back up condition
- SLU target current > 1000 mA
- model oil temperature >= 20°C
- common parameter, common condition (see Footnote: - Transmission Control Module --, 6-SPD, 09G (2011-2015 MY)).
|
|
|
| P0864 |
TCM Communication Circuit Range/Performance |
|
- detection of communication error (all frames which are entered in ATCU)
|
- ECU no communication for more than 50 ms (In case of repeat rate is over 25 ms, double value of repeat rate is used)
|
- CAN bus: ACTIVE
- time: 500 ms after ignition: ON
|
- 500 ms (In case of re peat rate is over 50 ms, 10 times value of repeat rate is used)
|
|
- detection of communication error (one frame which is entered in ATCU)
|
- ECU no communication for more than 50 ms (In case of repeat rate is over 25 ms, double value of repeat rate is used)
|
- CAN bus: ACTIVE
- time: 500 ms after ignition: ON
- ECU communication: not in no communication failure
|
- 1000 ms (In case of repeat rate is over 50 ms, 20 times value of repeat rate is used)
|
|
|
- ECU signal data freeze (data counter (ID488, Byte8, Bit7•••4) not updated)
|
|
- CAN bus: ACTIVE
- CAN data repeat rate: the space of time between two received messages has not exceeded double the transmission cycle time
|
- no update in five message
|
|
|
- detection of communication error
|
- no acknowledge condition for more than 300 ms
|
- CAN bus: ACTIVE
- time: 500 ms after ignition: ON
|
|
| P0865 |
TCM Communication Circuit Low |
|
- detection of communication error
|
- CAN BUS off condition for more than 250 ms
|
- time 500 ms after ignition: ON
|
|
|
| P2122 |
Throttle/Pedal Position Sensor/Switch "D" Circuit Low |
|
- detection of error signal
|
|
- CAN bus: ACTIVE
- ECU communication: ACTIVE
- ECU data update: ACTIVE
|
|
|
| P2637 |
Torque Management Feedback Signal "A" |
- CAN receive data check for "signal invalid"
|
- detection of error signal (0xFF)
|
|
- CAN bus: ACTIVE
- ECU communication: ACTIVE
- ECU data update: ACTIVE
|
|
|
| P2716 |
Pressure Control Solenoid "D" Electrical |
- Input AD value check in every Linear solenoid.
|
- detection of wrong input AD value
|
- feedback current > 1333 mA (AD value > 1000) for more than 100 ms
|
|
|
|
- feedback current < 23 mA (AD value < 15) for more than 100 ms
|
|
|
|
- Linear solenoid feedback current check
|
- comparison of target current and feedback current
|
- sum of difference of two current > 20000 Ω
|
- linear feedback current is > 23 mA (AD:15) < 1333 mA (AD:1000)
|
|
|
| P2725 |
Pressure Control Solenoid "E" Electrical |
- Input AD value check in every Linear solenoid.
|
- detection of wrong input AD value
|
- feedback current > 1333 mA (AD value > 1000) for more than 100 ms
|
|
|
|
- feedback current < 23 mA (AD value < 15) for more than 100 ms
|
|
|
|
- Linear solenoid feedback current check
|
- comparison of target current and feedback current
|
- sum of difference of two current > 20000 Ω
|
- linear feedback current is > 23 mA (AD:15) < 1333 mA (AD:1000)
|
|
|
| P2734 |
Pressure Control Solenoid "F" Electrical |
- Input AD value check in every Linear solenoid.
|
- detection of wrong input AD value
|
- feedback current > 1333 mA (AD value > 1000) for more than 100 ms
|
|
|
|
- feedback current < 23 mA (AD value < 15) for more than 100 ms
|
|
|
|
- Linear solenoid feedback current check
|
- comparison of target current and feedback current
|
- sum of difference of two current > 20000 Ω
|
- linear feedback current is > 23 mA (AD:15) < 1333 mA (AD:1000)
|
|
|