Monitor-ID $3D: EVAP Valve Function Check
-- Connect the scan tool.
-- Start the engine and run at idle.
-- Select "Mode 6: Check test the results of components that are not continuously monitored".
Select "Monitor-ID 3D".
-- Select the desired "Test-ID".
-- Check specified values at idle.
| Test-ID | DTC | Component or System | Min. | Max. | Additional Information |
|---|---|---|---|---|---|
| $80 | P0441 | Tank vent valve check from % DTEV: Active test Air balance at idle OK, (Normal operation and short test 70). | .350 | 1.999 | Refer to DTC P0441 in the DTC summary table. Engine Control Module --, 2010-2014 MY . |
| $82 | - | Tank vent valve check from % DTEV: Active test, Oxygen sensor regulator deviating in lean direction (can only test OK), (Normal operation and short test 70). | 1 | 65355 | Pass only. |
| $88 | - | Purge flow OK by deviation lambda control. | 1 | 65355 | Pass only. |
| $8C | P0441 | Purge flow monitor valve open | 0.0000 mA | 4.200 to 14.000 mA | Refer to DTC P0441 in the DTC summary table. Engine Control Module --, 2010-2014 MY . |
| $8D | P0441 | Purge flow monitor valve closed | 0.0000 mA | 4.300 to 36.3000 mA | Refer to DTC P0441 in the DTC summary table. Engine Control Module --, 2010-2014 MY . |
-- If any of components or systems fail to meet the specified values. Refer to Diagnostic "Mode 03: Interrogating Fault Memory" to check for stored DTC's or the corresponding diagnostic repair procedure DIAGNOSTIC MODE 03 - READ DTC MEMORY .
-- Switch the ignition off.