Home >> Volkswagen >> 2021 >> Atlas SE R-Line, AWD >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Generic Scan Tool (DTFA, DCGA) [Transmission DTC Tables] >> St Generic Scan Tool >> Diagnosis And Testing >> Transmission DTC Tables >> Transmission Control Module --, 7 SPEED DQ381-7A 0GC (2022 MY)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Transmission Control Module --, 7 SPEED DQ381-7A 0GC (2022 MY)

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Auxiliary Transmission Fluid Pump P0C2B - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal rationality check error flag of auxiliary transmission fluid pump rotational speed is set - ignition on via terminal 15 voltage, battery voltage higher minimum threshold, no failure of auxiliary transmission fluid pump CAN message terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt 20 ms 2 DCY
Auxiliary Transmission Fluid Pump P0C2B - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal rationality check error flag of auxiliary transmission fluid pump control is set - ignition on via terminal 15 voltage, battery voltage higher minimum threshold, no failure of auxiliary transmission fluid pump CAN message terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt 20 ms 2 DCY
COM: CAN-Bus U0002 - High Speed CAN Communication Bus Performance communication check time out of all messages time-out for more than 0.45 sec ignition on via terminal 15 voltage, battery voltage higher minimum threshold, battery voltage lower maximum threshold, no bus off error, time after reset, monitoring terminal 15 voltage terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt, time after reset > 1 sec, terminal 15 voltage > 9 Volt, terminal 15 voltage < 17 Volt 0.45 sec 1 DCY
COM: CAN-Bus U0001 - High Speed CAN Communication Bus communication check bus not active (bus off) bus not active for 3 events ignition on via terminal 15 voltage, battery voltage higher minimum threshold, battery voltage lower maximum threshold, time after reset, monitoring terminal 15 voltage terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt, time after reset > 1 sec, terminal 15 voltage > 9 Volt, terminal 15 voltage < 17 Volt 3 successive bus off states 1 DCY
COM: CAN-Bus U0287 - Lost Communication With Transmission Fluid Pump Module "A" communication check failure of main CAN auxiliary transmission fluid pump message "MTFP_01" time-out ignition on via terminal 15 voltage, no bus off error, no error failure of all CAN messages, time after reset, monitoring terminal 15 voltage terminal 15 voltage > 7.5 Volt, time after reset > 1 sec, terminal 15 voltage > 9 Volt, terminal 15 voltage < 17 Volt 2 sec 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
COM: CAN-Bus P2797 - Electric/Auxiliary Transmission Fluid Pump "A" Performance/Stuck Off communication check data length code of main CAN auxiliary transmission fluid pump message "MTFP_01" is too short data length code < 8 ignition on via terminal 15 voltage, no bus off error, no error failure of all CAN messages, time after reset, monitoring terminal 15 voltage terminal 15 voltage > 7.5 Volt, time after reset > 1 sec, terminal 15 voltage > 9 Volt, terminal 15 voltage < 17 Volt 2 sec 2 DCY
COM: Engine Control Module U0100 - Lost Communication With ECM/PCM "A" communication check failure of main CAN engine message "Motor_11" time-out ignition on via terminal 15 voltage, battery voltage higher minimum threshold, battery voltage lower maximum threshold, no bus off error, no error failure of all CAN messages, time after reset, monitoring terminal 15 voltage terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt, time after reset > 1 sec, terminal 15 voltage > 9 Volt, terminal 15 voltage < 17 Volt 0.5 sec 1 DCY
Clutch P0810 - Clutch Position Control Error functional check - pressure check hydraulic pressure of clutch 1 exceeds a maximum value pressure >= 15 bar battery voltage higher minimum threshold, battery voltage lower maximum threshold, no signal range check error of pressure sensor clutch 1 battery voltage > 9 Volt, battery voltage < 16.5 Volt 200 ms 2 DCY
Clutch P0810 - Clutch Position Control Error functional check - pressure check hydraulic pressure of clutch 2 exceeds a maximum value pressure >= 15 bar battery voltage higher minimum threshold, battery voltage lower maximum threshold, no signal range check error of pressure sensor clutch 2 battery voltage > 9 Volt, battery voltage < 16.5 Volt 200 ms 2 DCY
Clutch P0810 - Clutch Position Control Error functional check - unable to open integral of actual pressure of clutch 1 minus desired pressure minus drain exceeds a maximum value integral >= 0.1 bar. s no teach in active, desired pressure, actual pressure, engine running, pressure sensor valid desired pressure <= (adapted clutch slipping point + min (1 bar ; 2.4 bar)) actual pressure >= (adapted clutch slipping point + -0.1 bar) 300 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Clutch P0810 - Clutch Position Control Error functional check - unable to open integral of actual pressure of clutch 2 minus desired pressure minus drain exceeds a maximum value integral >= 0.1 bar. s no teach in active, desired pressure, actual pressure, engine running, pressure sensor valid desired pressure <= (adapted clutch slipping point + min (1 bar ; 2.4 bar)), actual pressure >= (adapted clutch slipping point + -0.1 bar) 300 ms 2 DCY
Clutch P0810 - Clutch Position Control Error functional check - unable to close the number of successive pressure buildup failure of clutch 1 reaches a maximum value counter >= 2 engine on, no teach in active, active gearbox subsystem 1, battery voltage higher minimum threshold, battery voltage lower maximum threshold, pressure sensor valid battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Clutch P0810 - Clutch Position Control Error functional check - unable to close the number of successive pressure buildup failure of clutch 2 reaches a maximum value counter >= 2 engine on, no teach in active, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, pressure sensor valid battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Clutch Pressure Sensor P0805 - Clutch Position Sensor "A" Circuit signal range check voltage pressure sensor clutch 1 out of range Voltage < 4% of sensor supply voltage OR Voltage > 97% of sensor supply voltage battery voltage higher minimum threshold, battery voltage lower maximum threshold battery voltage > 9 Volt, battery voltage < 16.5 Volt 300 ms 2 DCY
Clutch Pressure Sensor P0805 - Clutch Position Sensor "A" Circuit signal range check voltage pressure sensor clutch 2 out of range Voltage < 4% of sensor supply voltage OR Voltage > 97% of sensor supply voltage battery voltage higher minimum threshold, battery voltage lower maximum threshold battery voltage > 9 Volt, battery voltage < 16.5 Volt 300 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
      integrated distance of gear          
      shift fork 1 positioned out of   engine on,      
      neutral to border of neutral   no teach in active,      
      range during vehicle standstill   active gearbox subsystem 1,      
      or nearly standstill with   battery voltage higher      
      desired neutral position   minimum threshold,      
      or   battery voltage lower      
      integrated synchronizing slip   maximum threshold,      
      with gear shift fork 1 integral of distance> 3 mm*s no slipping point adaption,      
      positioned out of neutral or no signal range check error of      
      position range in unexpected integral of synchronizing slip > position sensor gearshift fork battery voltage > 9 Volt,    
Gear Actuator P072C - Stuck in Gear 1 functional check gear direction GssDiag_Schwellen_Intgrl_kl 1 battery voltage < 16.5 Volt 1 event 2 DCY
      integrated distance of gear          
      shift fork 2 positioned out of   engine on,      
      neutral to border of neutral   no teach in active,      
      range during vehicle standstill   active gearbox subsystem 2,      
      or nearly standstill with   battery voltage higher      
      desired neutral position   minimum threshold,      
      or   battery voltage lower      
      integrated synchronizing slip   maximum threshold,      
      with gear shift fork 2 integral of distance> 3 mm*s no slipping point adaption,      
      positioned out of neutral or no signal range check error of      
      position range in unexpected integral of synchronizing slip > position sensor gearshift fork battery voltage > 9 Volt,    
Gear Actuator P072D - Stuck in Gear 2 functional check gear direction GssDiag_Schwellen_Intgrl_kl 2 battery voltage < 16.5 Volt 1 event 2 DCY
      integrated distance of gear          
      shift fork 3 positioned out of   engine on,      
      neutral to border of neutral   no teach in active,      
      range during vehicle standstill   active gearbox subsystem 1,      
      or nearly standstill with   battery voltage higher      
      desired neutral position   minimum threshold,      
      or   battery voltage lower      
      integrated synchronizing slip   maximum threshold,      
      with gear shift fork 3 integral of distance> 3 mm*s no slipping point adaption,      
      positioned out of neutral or no signal range check error of      
      position range in unexpected integral of synchronizing slip > position sensor gearshift fork battery voltage > 9 Volt,    
Gear Actuator P072E - Stuck in Gear 3 functional check gear direction GssDiag_Schwellen_Intgrl_kl 3 battery voltage < 16.5 Volt 1 event 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Gear Actuator P072F - Stuck in Gear 4 functional check integrated distance of gear shift fork 4 positioned out of neutral to border of neutral range during vehicle standstill or nearly standstill with desired neutral position or integrated synchronizing slip with gear shift fork 4 positioned out of neutral position range in unexpected gear direction integral of distance > 3 mm*s or integral of synchronizing slip > GssDiag_Schwellen_Intgrl_kl engine on, no teach in active, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, no slipping point adaption, no signal range check error of position sensor gearshift fork 4 battery voltage > 9 Volt, battery voltage < 16.5 Volt 1 event 2 DCY
Gear Actuator P072C - Stuck in Gear 1 functional check number of successive failed attempts to engage the desired first gear >= 5 engine on, no teach in active, active gearbox subsystem 1, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Gear Actuator P072D - Stuck in Gear 2 functional check number of successive failed attempts to engage the desired second gear >= 5 engine on, no teach in active, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Gear Actuator P072E - Stuck in Gear 3 functional check number of successive failed attempts to engage the desired third gear >= 5 engine on, no teach in active, active gearbox subsystem 1, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Gear Actuator P072F - Stuck in Gear 4 functional check number of successive failed attempts to engage the desired fourth gear >= 5 engine on, no teach in active, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Gear Actuator P073A - Stuck in Gear 5 functional check number of successive failed attempts to engage the desired fifth gear >= 5 engine on, no teach in active, active gearbox subsystem 1, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Gear Actuator P073B - Stuck in Gear 6 functional check number of successive failed attempts to engage the desired sixth gear >= 5 engine on, no teach in active, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Gear Actuator P073C - Stuck in Gear 7 functional check number of successive failed attempts to engage the desired seventh gear >= 5 engine on, no teach in active, active gearbox subsystem 1, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Gear Actuator P072B - Stuck In Reverse functional check number of successive failed attempts to engage the desired reverse gear >= 5 engine on, no teach in active, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active, vehicle standstill battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Gear Actuator P073F - Unable to Engage Gear 1 functional check integral that corresponds to the energy flux in the synchronization during engage the desired first gear exceeds a maximum value integral > Gss_WMax_SyncArbeitUebrw g_kf no teach in active, active gearbox subsystem 1, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active, valid output speed information battery voltage > 9 Volt, battery voltage < 16.5 Volt 100 ms 2 DCY
Gear Actuator P074A - Unable To Engage Gear 2 functional check integral that corresponds to the energy flux in the synchronization during engage the desired second gear exceeds a maximum value integral > Gss_WMax_SyncArbeitUebrw g_kf no teach in active, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active, valid output speed information battery voltage > 9 Volt, battery voltage < 16.5 Volt 100 ms 2 DCY
Gear Actuator P074B - Unable To Engage Gear 3 functional check integral that corresponds to the energy flux in the synchronization during engage the desired third gear exceeds a maximum value integral > Gss_WMax_SyncArbeitUebrw g_kf no teach in active, active gearbox subsystem 1, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active, valid output speed information battery voltage > 9 Volt, battery voltage < 16.5 Volt 100 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
          no teach in active,      
          active gearbox subsystem 2,      
          battery voltage higher      
      integral that corresponds to   minimum threshold,      
      the energy flux in the   battery voltage lower      
      synchronization during   maximum threshold,      
      engage the desired fourth integral > adaption via adaption      
      gear exceeds a maximum Gss_WMax_SyncArbeitUebrw manager not active, battery voltage > 9 Volt,    
Gear Actuator P074C - Unable To Engage Gear 4 functional check value g_kf valid output speed information battery voltage < 16.5 Volt 100 ms 2 DCY
          no teach in active,      
          active gearbox subsystem 1,      
          battery voltage higher      
          minimum threshold,      
      integral that corresponds to   battery voltage lower      
      the energy flux in the   maximum threshold,      
      synchronization during integral > adaption via adaption      
      engage the desired fifth gear Gss_WMax_SyncArbeitUebrw manager not active, battery voltage > 9 Volt,    
Gear Actuator P074D - Unable To Engage Gear 5 functional check exceeds a maximum value g_kf valid output speed information battery voltage < 16.5 Volt 100 ms 2 DCY
          no teach in active,      
          active gearbox subsystem 2,      
          battery voltage higher      
          minimum threshold,      
      integral that corresponds to   battery voltage lower      
      the energy flux in the   maximum threshold,      
      synchronization during integral > adaption via adaption      
      engage the desired sixth gear Gss_WMax_SyncArbeitUebrw manager not active, battery voltage > 9 Volt,    
Gear Actuator P074E - Unable To Engage Gear 6 functional check exceeds a maximum value g_kf valid output speed information battery voltage < 16.5 Volt 100 ms 2 DCY
          no teach in active,      
          active gearbox subsystem 1,      
          battery voltage higher      
      integral that corresponds to   minimum threshold,      
      the energy flux in the   battery voltage lower      
      synchronization during   maximum threshold,      
      engage the desired seventh integral > adaption via adaption      
      gear exceeds a maximum Gss_WMax_SyncArbeitUebrw manager not active, battery voltage > 9 Volt,    
Gear Actuator P074F - Unable To Engage Gear 7 functional check value g_kf valid output speed information battery voltage < 16.5 Volt 100 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
          no teach in active,      
          active gearbox subsystem 2,      
          battery voltage higher      
      integral that corresponds to   minimum threshold,      
      the energy flux in the   battery voltage lower      
      synchronization during   maximum threshold,      
      engage the desired reverse integral > adaption via adaption      
      gear exceeds a maximum Gss_WMax_SyncArbeitUebrw manager not active, battery voltage > 9 Volt,    
Gear Actuator P073E - Stuck in Gear 3 functional check value g_kf valid output speed information battery voltage < 16.5 Volt 100 ms 2 DCY
          engine on,      
          no teach in active,      
          active gearbox subsystem 1,      
        time > battery voltage higher      
        Gss_T_UebrwgLimitSync_kl, minimum threshold,      
        Gss_T_UebrwgLimitPMaxSyn battery voltage lower      
        c_kl, maximum threshold,      
      time to engage neutral Gss_T_UebrwgLimitEinlgn_kl adaption via adaption      
      position of gearshift fork 1 in , manager not active,      
      spite of maximum setting Gss_T_UebrwgLimitPMaxEinl not two gears engaged on battery voltage > 9 Volt,    
Gear Actuator P072C - Stuck in Gear 1 functional check pressure elapsed gn_kl shaft 1 battery voltage < 16.5 Volt 20 ms 2 DCY
          engine on,      
          no teach in active,      
          active gearbox subsystem 2,      
        time > battery voltage higher      
        Gss_T_UebrwgLimitSync_kl, minimum threshold,      
        Gss_T_UebrwgLimitPMaxSyn battery voltage lower      
        c_kl, maximum threshold,      
      time to engage neutral Gss_T_UebrwgLimitEinlgn_kl adaption via adaption      
      position of gearshift fork 2 in , manager not active,      
      spite of maximum setting Gss_T_UebrwgLimitPMaxEinl not two gears engaged on battery voltage > 9 Volt,    
Gear Actuator P072D - Stuck in Gear 2 functional check pressure elapsed gn_kl shaft 2 battery voltage < 16.5 Volt 20 ms 2 DCY
          engine on,      
          no teach in active,      
          active gearbox subsystem 1,      
        time > battery voltage higher      
        Gss_T_UebrwgLimitSync_kl, minimum threshold,      
        Gss_T_UebrwgLimitPMaxSyn battery voltage lower      
        c_kl, maximum threshold,      
      time to engage neutral Gss_T_UebrwgLimitEinlgn_kl adaption via adaption      
      position of gearshift fork 3 in , manager not active,      
      spite of maximum setting Gss_T_UebrwgLimitPMaxEinl not two gears engaged on battery voltage > 9 Volt,    
Gear Actuator P072E - Stuck in Gear 3 functional check pressure elapsed gn_kl shaft 1 battery voltage < 16.5 Volt 20 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Gear Actuator P072F - Stuck in Gear 4 functional check time to engage neutral position of gearshift fork 4 in spite of maximum setting pressure elapsed time > Gss_T_UebrwgLimitSync_kl, Gss_T_UebrwgLimitPMaxSyn c_kl, Gss_T_UebrwgLimitEinlgn_kl, Gss_T_UebrwgLimitPMaxEinl gn_kl engine on, no teach in active, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, adaption via adaption manager not active, not two gears engaged on shaft 2 battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Gear Actuator P0893 - Multiple Gears Engaged rationality check unsuccessful gear disengagement with two gears engaged at gearbox subsystem 1 - ignition on via terminal 15 voltage, no teach in active, battery voltage higher minimum threshold, battery voltage lower maximum threshold terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt 2000 ms 2 DCY
Gear Actuator P0893 - Multiple Gears Engaged rationality check unsuccessful gear disengagement with two gears engaged at gearbox subsystem 2 - ignition on via terminal 15 voltage, no teach in active, battery voltage higher minimum threshold, battery voltage lower maximum threshold terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt 2000 ms 2 DCY
Gear Position Sensor P0607 - Control Module Performance signal range check voltage position sensor gearshift fork 1 out of range Voltage < 2% of sensor supply voltage OR Voltage > 98% of sensor supply voltage battery voltage higher minimum threshold, battery voltage lower maximum threshold, sensor supply voltage battery voltage > 9 Volt, battery voltage < 16.5 Volt, sensor supply voltage > 4.48 V AND < 4.92 V 200 ms 2 DCY
Gear Position Sensor P0607 - Control Module Performance signal range check voltage position sensor gearshift fork 2 out of range Voltage < 2% of sensor supply voltage OR Voltage > 98% of sensor supply voltage battery voltage higher minimum threshold, battery voltage lower maximum threshold, sensor supply voltage battery voltage > 9 Volt, battery voltage < 16.5 Volt, sensor supply voltage > 4.48 V AND < 4.92 V 200 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Gear Position Sensor P0607 - Control Module Performance signal range check voltage position sensor gearshift fork 3 out of range Voltage < 2% of sensor supply voltage OR Voltage > 98% of sensor supply voltage battery voltage higher minimum threshold, battery voltage lower maximum threshold, sensor supply voltage battery voltage > 9 Volt, battery voltage < 16.5 Volt, sensor supply voltage > 4.48 V AND < 4.92 V 200 ms 2 DCY
Gear Position Sensor P0607 - Control Module Performance signal range check voltage position sensor gearshift fork 4 out of range Voltage < 2% of sensor supply voltage OR Voltage > 98% of sensor supply voltage battery voltage higher minimum threshold, battery voltage lower maximum threshold, sensor supply voltage battery voltage > 9 Volt, battery voltage < 16.5 Volt, sensor supply voltage > 4.48 V AND < 4.92 V 200 ms 2 DCY
Selector Lever U0103 - Lost Communication With Gear Shift Control Module "A" communication check failure of selector lever CAN message "Waehlhebel_03" time-out battery voltage higher minimum threshold, battery voltage lower maximum threshold, no bus off error, no error failure of all CAN messages, time after reset, monitoring terminal 15 voltage battery voltage > 9 Volt, battery voltage < 16.5 Volt, time after reset > 1 sec, terminal 15 voltage > 9 Volt, terminal 15 voltage < 17 Volt 0.2 sec 2 DCY
Selector Lever P0914 - Gear Shift Position Circuit "A" communication check selector lever position is not equal to negation of the inverse selector lever position or selector lever position equals initialization value or selector lever position equals error value or selector lever position is equal to negation of the inverse selector lever position but invalid position ((1) Position_1, (2) Position_2, (3) Position_3, (4) unactuated or (13) Position_L) - battery voltage higher minimum threshold, battery voltage lower maximum threshold, no bus off error, no error failure of all CAN messages, no failure of selector lever CAN message, time after reset, monitoring terminal 15 voltage battery voltage > 9 Volt, battery voltage < 16.5 Volt, time after reset > 1 sec + 100 ms + 500 ms, terminal 15 voltage > 9 Volt, terminal 15 voltage < 17 Volt 1200 ms + 20 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Selector Lever P0914 - Gear Shift Position Circuit "A" communication check failure of question and answer diagnosis - battery voltage higher minimum threshold, battery voltage lower maximum threshold, no bus off error, no error failure of all CAN messages, no failure of selector lever CAN message, time after reset, monitoring terminal 15 voltage battery voltage > 9 Volt, battery voltage < 16.5 Volt, time after reset > 1 sec + 100 ms + 500 ms, terminal 15 voltage > 9 Volt, terminal 15 voltage < 17 Volt 1500 ms + 20 ms 2 DCY
Selector Lever P0919 - Gear Shift Position Control Error communication check error flag of not determinable selector lever position is set in the error signal of selector lever CAN message - battery voltage higher minimum threshold, battery voltage lower maximum threshold, no failure of selector lever CAN message battery voltage > 9 Volt, battery voltage < 16.5 Volt 20 ms 2 DCY
Selector Lever U0404 - Invalid Data Received From Gear Shift Control Module "A" communication check if the value of selector lever CAN message counter is permanent constant or change exceeds a threshold increment an event counter maximum change of message counter > 3 battery voltage higher minimum threshold, battery voltage lower maximum threshold, no failure of selector lever CAN messages battery voltage > 9 Volt, battery voltage < 16.5 Volt 5 events 2 DCY
Selector Lever P0919 - Gear Shift Position Control Error communication check if the selector lever position is not equal to negation of the inverse selector lever position or selector lever position equals initialization value but the initialization flag is not set or selector lever position equals error value then increment an event counter - battery voltage higher minimum threshold, battery voltage lower maximum threshold, no failure of selector lever CAN messages battery voltage > 9 Volt, battery voltage < 16.5 Volt 10 events 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Selector Lever P0919 - Gear Shift Position Control Error communication check if the selector lever position is equal to negation of the inverse selector lever position but is not valid (position == ((1) Position_1 or (2) Position_2 or (3) Position_3 or (4) unactuated or (13) Position_L) and is not in error state (position != error) and equals not the initialization value with the initialization flag not set then increment an event counter - battery voltage higher minimum threshold, battery voltage lower maximum threshold, no failure of selector lever CAN messages battery voltage > 9 Volt, battery voltage < 16.5 Volt 2 events 2 DCY
Selector Lever P0919 - Gear Shift Position Control Error communication check if the shift lock position signal in selector lever CAN message is not valid (position!= error, deactive, active or init) increment an event counter - battery voltage higher minimum threshold, battery voltage lower maximum threshold, no failure of selector lever CAN messages battery voltage > 9 Volt, battery voltage < 16.5 Volt 2 events 2 DCY
Selector Lever P0919 - Gear Shift Position Control Error communication check if time out of the question and answer diagnosis is detected increment an event counter time out threshold > 250 ms battery voltage higher minimum threshold, battery voltage lower maximum threshold, transmission control unit CAN- message for selector lever is transmittable and selector lever CAN-message is receivable, no failure of selector lever CAN messages, time after reset battery voltage > 9 Volt, battery voltage < 16.5 Volt, time after reset > 100 ms 1 event 2 DCY
Selector Lever P0919 - Gear Shift Position Control Error communication check if the answer of the question/answer diagnosis is wrong an event counter is incremented - battery voltage higher minimum threshold, battery voltage lower maximum threshold, no failure of selector lever CAN messages battery voltage > 9 Volt, battery voltage < 16.5 Volt 2 events 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold,      
    circuit continuity check - short current of solenoid clutch 1   current stable for more than battery voltage > 9 Volt,    
Solenoid P0747 - Pressure Control Solenoid "A" Stuck On to battery plus lower than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold,      
    circuit continuity check - short current of solenoid clutch 2   current stable for more than battery voltage > 9 Volt,    
Solenoid P0777 - Pressure Control Solenoid "B" Stuck On to battery plus lower than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold,      
    circuit continuity check - short current of gearshift fork valve   current stable for more than battery voltage > 9 Volt,    
Solenoid P0751 - Shift Solenoid "A" Performance/Stuck Off to battery plus 1 lower than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold,      
    circuit continuity check - short current of gearshift fork valve   current stable for more than battery voltage > 9 Volt,    
Solenoid P0756 - Shift Solenoid "B" Performance/Stuck Off to battery plus 2 lower than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold,      
    circuit continuity check - short current of gearshift fork valve   current stable for more than battery voltage > 9 Volt,    
Solenoid P0761 - Shift Solenoid "C" Performance/Stuck Off to battery plus 3 lower than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold,      
    circuit continuity check - short current of gearshift fork valve   current stable for more than battery voltage > 9 Volt,    
Solenoid P0766 - Shift Solenoid "D" Performance/Stuck Off to battery plus 4 lower than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold,      
    circuit continuity check - short current of safety valve 1 lower   current stable for more than battery voltage > 9 Volt,    
Solenoid P2723 - Pressure Control Solenoid "E" Performance/Stuck Off to battery plus than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold,      
    circuit continuity check - short current of safety valve 2 lower   current stable for more than battery voltage > 9 Volt,    
Solenoid P2732 - Pressure Control Solenoid "F" Performance/Stuck Off to battery plus than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          ignition on via terminal 15      
          voltage,      
          active gearbox subsystem 1,      
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold, terminal 15 voltage > 7.5 Volt,    
    circuit continuity check - open current of solenoid clutch 1   current stable for more than battery voltage > 9 Volt,    
Solenoid P0746 - Pressure Control Solenoid "A" Performance/Stuck Off circuit higher than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          ignition on via terminal 15      
          voltage,      
          active gearbox subsystem 2,      
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold, terminal 15 voltage > 7.5 Volt,    
    circuit continuity check - open current of solenoid clutch 2   current stable for more than battery voltage > 9 Volt,    
Solenoid P0776 - Pressure Control Solenoid "B" Performance/Stuck Off circuit higher than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          ignition on via terminal 15      
          voltage,      
          active gearbox subsystem 1,      
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold, terminal 15 voltage > 7.5 Volt,    
    circuit continuity check - open current of gearshift fork valve   current stable for more than battery voltage > 9 Volt,    
Solenoid P0751 - Shift Solenoid "A" Performance/Stuck Off circuit 1 higher than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY
          ignition on via terminal 15      
          voltage,      
          active gearbox subsystem 2,      
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
      voltage to adjust nominal   maximum threshold, terminal 15 voltage > 7.5 Volt,    
    circuit continuity check - open current of gearshift fork valve   current stable for more than battery voltage > 9 Volt,    
Solenoid P0756 - Shift Solenoid "B" Performance/Stuck Off circuit 2 higher than expected - 100 ms battery voltage < 16.5 Volt 360 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Solenoid P0761 - Shift Solenoid "C" Performance/Stuck Off circuit continuity check - open circuit voltage to adjust nominal current of gearshift fork valve 3 higher than expected - ignition on via terminal 15 voltage, active gearbox subsystem 1, battery voltage higher minimum threshold, battery voltage lower maximum threshold, current stable for more than 100 ms terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt 360 ms 2 DCY
Solenoid P0766 - Shift Solenoid "D" Performance/Stuck Off circuit continuity check - open circuit voltage to adjust nominal current of gearshift fork valve 4 higher than expected - ignition on via terminal 15 voltage, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, current stable for more than 100 ms terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt 360 ms 2 DCY
Solenoid P2723 - Pressure Control Solenoid "E" Performance/Stuck Off circuit continuity check - open circuit voltage to adjust nominal current of safety valve 1 higher than expected - ignition on via terminal 15 voltage, active gearbox subsystem 1, battery voltage higher minimum threshold, battery voltage lower maximum threshold, current stable for more than 100 ms terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt 360 ms 2 DCY
Solenoid P2732 - Pressure Control Solenoid "F" Performance/Stuck Off circuit continuity check - open circuit voltage to adjust nominal current of safety valve 2 higher than expected - ignition on via terminal 15 voltage, active gearbox subsystem 2, battery voltage higher minimum threshold, battery voltage lower maximum threshold, current stable for more than 100 ms terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt 360 ms 2 DCY
Supply Voltage Monitoring P0607 - Control Module Performance signal range check sensor voltage supply 1 out of range U sensor < 4000 mV OR U sensor > 5900 mV battery voltage higher minimum threshold, battery voltage lower maximum threshold battery voltage > 9 Volt, battery voltage < 16.5 Volt 100 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Supply Voltage Monitoring P0607 - Control Module Performance signal range check sensor voltage supply 2 out of range U sensor < 4000 mV OR U sensor > 5900 mV battery voltage higher minimum threshold, battery voltage lower maximum threshold battery voltage > 9 Volt, battery voltage < 16.5 Volt 100 ms 2 DCY
Transmission Control Module (TCM) P0607 - Control Module Performance ECU internal hardware check microcontroller reports switch- off path error of safety processor after single switch- off path test every system startup - battery voltage higher minimum threshold, battery voltage lower maximum threshold, system start-up battery voltage > 9 Volt, battery voltage < 16.5 Volt 1 event 2 DCY
Transmission Control Module (TCM) P0607 - Control Module Performance ECU internal hardware check transmission control module stays switched on in spite of cutoff command - control module overshoot time, ignition off via terminal 15 - 300 ms 1 DCY
Transmission Control Module (TCM) P0607 - Control Module Performance ECU internal hardware check short circuit to ground of common high side switch 1 - battery voltage higher minimum threshold, battery voltage lower maximum threshold, common high side switch 1 on battery voltage battery voltage > 9 Volt, battery voltage < 16.5 Volt, battery voltage > 9.2 V, battery voltage < 16.5 V 400 ms 2 DCY
Transmission Control Module (TCM) P0607 - Control Module Performance ECU internal hardware check short circuit to ground of common high side switch 2 - battery voltage higher minimum threshold, battery voltage lower maximum threshold, common high side switch 2 on, battery voltage battery voltage > 9 Volt, battery voltage < 16.5 Volt, battery voltage > 9.2 V, battery voltage < 16.5 V 400 ms 2 DCY
Transmission Control Module (TCM): EEPROM P0607 - Control Module Performance ECU EEPROM-check bios reports NVM error - - - 20 ms 1 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
Transmission Control Module (TCM): Processor P0607 - Control Module Performance ECU internal hardware check microcontroller reports instruction set error - battery voltage higher minimum threshold, battery voltage lower maximum threshold battery voltage > 9 Volt, battery voltage < 16.5 Volt 2 watchdog resets 2 DCY
Transmission Control Module (TCM): Production Mode U1103 - Production Mode Active communication check in production process necessary special mode is activated - - - 20 ms 1 DCY
Transmission Control Module (TCM): ROM P0605 - Internal Control Module Memory Checksum Error ECU ROM-check microcontroller reports ROM error - battery voltage higher minimum threshold, battery voltage lower maximum threshold battery voltage > 9 Volt, battery voltage < 16.5 Volt checksum error: 1 error event ECC error: 2 error events 2 DCY
Transmission Control Module (TCM): Speed Sensor P0791 - Intermediate Shaft Speed Sensor "A" Circuit circuit continuity check - open circuit no rotational speed detection at shaft 1 rotational speed <= 0 U/min ignition on via terminal 15 voltage, engine on, battery voltage higher minimum threshold, battery voltage lower maximum threshold, valid CAN output speed information, gear engaged on input shaft 1, wheel speed, speed differential between all wheels terminal 15 voltage > 7.5 Volt, battery voltage > 9 Volt, battery voltage < 16.5 Volt, wheel speed > 10 km/h, speed differential between all wheels < 3 km/h 460 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
          ignition on via terminal 15      
          voltage,      
          engine on,      
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
          maximum threshold,      
          valid CAN output speed terminal 15 voltage > 7.5 Volt,    
          information, battery voltage > 9 Volt,    
          gear engaged on input shaft 2, battery voltage < 16.5 Volt,    
          wheel speed, wheel speed > 10 km/h,    
Transmission Control Module   circuit continuity check - open no rotational speed detection   wheel speed differential speed differential between all    
(TCM): Speed Sensor P0791 - Intermediate Shaft Speed Sensor "A" Circuit circuit at shaft 2 rotational speed <= 0 U/min between all wheels wheels < 3 km/h 460 ms 2 DCY
          battery voltage higher      
          minimum threshold,      
Transmission Control Module     rotational speed of input shaft rotational speed > 11800 battery voltage lower battery voltage > 9 Volt,    
(TCM): Speed Sensor P0791 - Intermediate Shaft Speed Sensor "A" Circuit signal range check 1 exceeds a maximum value U/min maximum threshold battery voltage < 16.5 Volt 80 ms 2 DCY
          battery voltage higher      
          minimum threshold,      
Transmission Control Module     rotational speed of input shaft rotational speed > 11800 battery voltage lower battery voltage > 9 Volt,    
(TCM): Speed Sensor P0791 - Intermediate Shaft Speed Sensor "A" Circuit signal range check 2 exceeds a maximum value U/min maximum threshold battery voltage < 16.5 Volt 80 ms 2 DCY
          battery voltage higher      
      sensor voltage supply of   minimum threshold,      
Transmission Control Module     speed sensor input shaft 1 out   battery voltage lower battery voltage > 9 Volt,    
(TCM): Speed Sensor P0715 - Input/Turbine Shaft Speed Sensor "A" Circuit rationality check of range - maximum threshold battery voltage < 16.5 Volt 300 ms 2 DCY
          battery voltage higher      
      sensor voltage supply of   minimum threshold,      
Transmission Control Module     speed sensor input shaft 2 out   battery voltage lower battery voltage > 9 Volt,    
(TCM): Speed Sensor P2765 - Input/Turbine Shaft Speed Sensor "B" Circuit rationality check of range - maximum threshold battery voltage < 16.5 Volt 300 ms 2 DCY
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
          maximum threshold,      
          sensor voltage supply of      
Transmission Control Module   circuit continuity check - short short circuit speed sensor   speed sensor input shaft 1 battery voltage > 9 Volt,    
(TCM): Speed Sensor P0715 - Input/Turbine Shaft Speed Sensor "A" Circuit circuit input shaft 1 - valid battery voltage < 16.5 Volt 300 ms 2 DCY

Table continues below

Component / System Fault Code / Description Monitor Strategy Malfunction Criteria Threshold Value Secondary Parameters Enable Conditions Monitor Time Length MIL Illumination
          battery voltage higher      
          minimum threshold,      
          battery voltage lower      
          maximum threshold,      
          sensor voltage supply of      
Transmission Control Module   circuit continuity check - short short circuit speed sensor   speed sensor input shaft 2 battery voltage > 9 Volt,    
(TCM): Speed Sensor P2765 - Input/Turbine Shaft Speed Sensor "B" Circuit circuit input shaft 2 - valid battery voltage < 16.5 Volt 300 ms 2 DCY