Checking for an open-circuit
- Check cable between #B40 and relay base terminal 4 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been remedied.
- Continue
Refer to Information
- Check cable between fuse 31 and air conditioning (A/C) relay (2/22) terminal 1 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been remedied.
- Continue
Refer to Information
- Check cable between air conditioning (A/C) switch terminal 2 and air conditioning (A/C) relay terminal 1 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been repaired.
- Continue
Refer to Information
- Check cable between fuse 31 and air conditioning (A/C) switch terminal 1 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been remedied.
- Continue
Refer to Information
- Check cable between air conditioning (A/C) relay terminal 2 and ECC control module (4/30) #B11 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been remedied.
- Continue
Refer to Information
- Check cable between blower fan switch terminal B1 and air conditioning (A/C) relay terminal 2 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been remedied.
- Continue
Refer to Information
- Check cable between fuse 31 and blower fan switch terminal A4 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been remedied.
- Continue
Refer to Information
- Check cable between relay (2/22) terminal 3 and pressure switch (Pressostat) (7/53) terminal 1 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been remedied.
- Continue
Refer to Information
- Check cable between pressure switch (Pressostat) (7/53) terminal 2 and compressor (8/3) connector for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been remedied.
- Continue
Refer to Information
- Check cable between pressure switch (Pressostat) (7/53) terminal 2 and compressor connector for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been remedied.
- Continue
Refer to Information