Intermittent fault
- Ignition off.
Check cable between control module #A51 and lock-up solenoid SL for an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults .
HINT: With the ignition off and control module disconnected the resistance between control module #A51 and ground (breakout box #53) should be 11-15 Ω.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting breakout box, Transmission control module (TCM) .
- To disconnect transmission connector, see Inspecting/cable harness to solenoids .
- For information about signals, see Signal specification, Transmission control module (TCM) .
Select Continue when the fault has been remedied.
- Continue