Checking The Ground Terminal
- Ignition off
- Main unit disconnected.
- Switch off all equipment that takes power from the battery (courtesy lighting, radio etc).
Connect an ohmmeter between terminal #18 on the breakout box and the battery negative terminal.
The ohmmeter should read approximately 0 Ω.
- OK
OKAY: Troubleshooting has been completed.
- NOT OK
Refer to CHECKING FOR OPEN-CIRCUITS, CONTACT RESISTANCE AND OXIDATION