Home >> Volvo >> 2004 >> S60 Base, 2.4 64 >> Repair and Diagnosis (Single Page) >> Electrical >> Body Electrical >> Central Electronic Module (CEM), Rear Electronic Module (Rem), Upper Electronics Module (UEM) - Diagnostic Trouble Codes - 6 Of 13 >> CEM-5F3D: Heater Fan. Signal Too Low (B5204T5; 2004) >> Signal too low >> Checks >> Intermittent fault
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Intermittent fault

Check the electrical terminals on the combustion fan and the control module connector. Check for contact resistance and oxidation.

Check the cable between control module terminal #10 and the signal terminal for the combustion fan (the black lead from the fan). Check for an intermittent open-circuit. Check for an intermittent short-circuit to ground.

Check the cable between control module terminal #11 and the voltage terminal for the combustion fan (the red cable from the fan). Check for an intermittent open-circuit.

Remedy as necessary.

Other information: 

Fig 1: Identifying Data Link Connector
GLL102417Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Ohmmeter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.