Checking The Relay
- Ignition off.
Check that relay 2/61 is installed correctly. At the same time check the relay connections, in particular 2/61 2, for:
diagnostic trouble code CEM-8B01
short circuit to voltage supply as described in, see SHORT-CIRCUIT TO SUPPLY VOLTAGE. PERMANENT FAULTS .
diagnostic trouble code CEM-8B03
open circuit as described in, see OPEN-CIRCUIT, PERMANENT FAULTS .
Do the necessary corrective action.
Additional information:
- To replace relay:
- For -2004, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING
- For 2005-, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- To connect the test box, see CONNECTING THE BREAKOUT BOX .
- To replace relay:
Is there a fault?
- YES
Refer to VERIFICATION
- NO
Refer to REPLACING THE COMPONENT