Checking The Component
If the fault is intermittent, it has been registered previously but is no longer present. Intermittent faults can occur for a number of different reasons. The fault is evaluated depending on how it occurs.
Check the signal cable between control module terminal #A13 and the control module in the rear door terminal #6. Check for a short-circuit to ground.
Check the signal cable between control module terminal #A13 and the control module in the rear door terminal #6. Check for a short-circuit to supply voltage.
Replace the signal cable if a fault is found.
If no fault was found, replace the control module in the rear door.
Remedy as necessary.
Other information:
- see ELECTRIC MOTOR, LIFT MECHANISM, SIDE WINDOW REAR
- see SIGNAL SPECIFICATION
- see CHECKING WIRING AND TERMINALS
- Continue
Refer to VERIFICATION POWER WINDOW MECHANISM