Checking The Ground Terminal
- Ignition off
- Control module disconnected
- Switch off all equipment that takes power from the battery (courtesy lighting, radio etc).
Connect the breakout box.
Connect an ohmmeter between terminal #A2 on the breakout box and the battery negative terminal.
The ohmmeter should read 0 Ω.
Other information
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX .
Is the value OK?
- YES
OKAY: Troubleshooting has been completed.
- NO
Refer to CHECKING FOR OPEN-CIRCUITS, CONTACT RESISTANCE AND OXIDATION