Connecting The Breakout Box
- Ignition off
- Remove fuses F3, F4, F12, F16 and F18 from the integrated relay/fusebox in the engine compartment
- To expose the connectors for the central electronic module (CEM), see:
Connect breakout box see 9511428 to the adapter.
Disconnect the breakout box in reverse order.
NOTE:
Before the control module can be checked and measurements taken, the removed fuses must first be reinstalled.
Central electronic module (CEM)
- Connect adapter see 9512899 to control module connectors A, B, C, D, E, F, G and H.
- For connector A, terminals #A1-#A46 correspond to terminals #1-#46 in the breakout box, when the breakout box is connected to output A
- For connector B, terminals #B1-#B32 correspond to terminals #1-#32 in the breakout box, when the breakout box is connected to output B
- For connector C, terminals #C1-#C46 correspond to terminals #1-#46 in the breakout box, when the breakout box is connected to output C
- For connector D, terminals #D1-#D14 correspond to terminals #1-#14 in the breakout box, when the breakout box is connected to output D/H
- For connector E, terminals #E1-#E41 correspond to terminals #1-#41 in the breakout box, when the breakout box is connected to output E
- For connector F, terminals #F1-#F32 correspond to terminals #1-#32 in the breakout box, when the breakout box is connected to output F
- For connector G, terminals #G1-#G32 correspond to terminals #1-#32 in the breakout box, when the breakout box is connected to output G
- For connector H, terminals #H1-#H32 correspond to terminals #15-#46 in the breakout box, when the breakout box is connected to output D/H.
Other information