Condition, Fuel Trim Bank X:
Fuel trim can assume 5 different conditions:
- No fuel trim, the start conditions have not been met. This condition occurs at the crank or immediately after start before fuel trim has started.
- Fuel trim with two probes. This situation occurs during driving when both probes are used during fuel trim (part load)
- No fuel trim, operation with predefined values. This situation occurs during hard acceleration or during fuel shut-off when there is no fuel trim and operation is under predefined values
- No fuel trim, operation with system error. This situation occurs when an earlier diagnostic trouble code (DTC) was stored that caused the fuel trim to be disabled
- Fuel trim with one probe (front). This situation occurs at idling speed or during light acceleration when one probe (front) is used during fuel trim.