Home >> Volvo >> 2007 >> S60 Base, AWD >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Accessories Control Systems >> Control Modules - Signal Specifications >> Signal Specification, Upper Electronic Module (UEM) (2001-2009) >> Signal Specification >> Upper Electronic Module (UEM)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Upper Electronic Module (UEM)

Fig 1: Identifying Connector F Terminals
GLL104034Courtesy of VOLVO CARS OF NORTH AMERICA.

Connector A, terminals #A1-#A22

The following values are measured between the relevant terminal in column 1 and terminal #A20 (signal ground) unless otherwise stated.

NOTE:

Check the ground terminals before starting to take readings with the breakout box.

U = DC in volts (V).

Ubat = battery voltage in volts (V).

Ulow = Voltage close to 0 V.

Terminal, breakout box Terminal, control module Signal type Ignition off
Active / not active
Ignition on
Active / not active
Other
#1 #A1 Power supply Ubat Ubat  
#2 #A2 Third row reading lamps, control signal (XC90 only) Ubat/0 Ubat/0  
#3 #A3  
Control module communication cable (CANH)
2.5-3.5 V 2.5-3.5 V During communication.
#4 #A4 The front right reading lamp and general lighting, control signal 7-9 V/0 V 7-9 V/0 V Active when the right front reading lamp or the general lighting is activated.
#5 #A5 Control modules communication cable (CANL) 1.5-2.5 V 1.5-2.5 V  
#6 #A6 The front right reading lamp, signal supply Ubat/0 V Ubat/0 V Pulse width modulation (PWM) signal.
#7 #A7 Rear left reading lamp, signal supply Ubat/0 V Ubat/0 V Active when the left rear reading lamp or the general lighting is activated. Pulse width modulation (PWM) signal.
#8 #A8 Extended X-supply Ubat/0 V Ubat/0 V The power supply to the sun roof logic, mirror lamps in the sun visor, rain sensor, buttons for the headlining lighting and certain button lighting.
#9 #A9 Cargo compartment lighting (V70, V70 XC) / Third row reading lamps (XC90), power supply Ubat/0 V Ubat/0 V Pulse width modulation (PWM) signal.
#10 #A10 Mass movement sensor, power supply Ubat/0 V Ubat/0 V Supplies power to both mass movement sensors in the XC90.
#11 #A11 Control module power supply Ubat Ubat  
#12 #A12 Control module power supply Ubat Ubat  
#13 #A13 Rain sensor, data signal - -  
#14 #A14 Rear right reading lamp, signal supply Ubat/0 V Ubat/0 V The signal is active when the button for the lamp is not pressed in.
#15 #A15 Rear left reading lamp, control signal Ubat/0 V Ubat/0 V The signal is active when the button for the lamp is not pressed in.
#16 #A16 The front left reading lamp and general lighting, control signal 7-9 V/0 V 7-9 V/0 V Active when the left front reading lamp or the general lighting is activated.
#17 #A17 The rear right reading lamp, signal supply Ubat/0 V Ubat/0 V Active when the right rear reading lamp or the general lighting is activated. Pulse width modulation (PWM) signal.
#18 #A18 The front left reading lamp, signal supply Ubat/0 V Ubat/0 V Pulse width modulation (PWM) signal.
#19 #A19 General lighting, signal supply Ubat/0 V Ubat/0 V Pulse width modulation (PWM) signal.
#20 #A20 Signal ground U Ulow U Ulow  
#21 #A21 Serial communication (Volcano lite) 0 V-Ubat 0 V-Ubat The voltage is 0 V - Ubat during communication. Ubat is the default.
#22 #A22 Mass movement sensor, data signal Ubat Ubat Communication with both mass movement sensors in the XC90.