Checking Control Module For Open-Circuits
Remove relay 2/117.
Check the driver circuit for the relay coil for an intermittent open-circuit as follows:
Measure the voltage between terminals #1 and #2 on the relay base.
For further information about intermittent open-circuits, see Open-circuit, intermittent faults .
Activate the relay driver for the rear window up: Click on the VCT2000 symbol.
HINT: The voltage between terminals #1 and #2 should be battery voltage.
If the value deviates excessively, check the voltage between terminal #2 and the battery and between terminal #1 and ground. Both should equal battery voltage. Check for an intermittent open-circuit according to Open-circuit, intermittent faults . Do not forget to check that the power supply to the control module is OK.
Other information
- Continue
Refer to Information