Checking Cable
- Ignition off.
Check the cable between the central electronic module (CEM) terminal #17D and the hazard warning signal flasher switch terminal #1 (3/6). Check for a short-circuit to ground.
Remedy as necessary.
Other information:
- For information about the central electronic module (CEM) connector, see Central electronic module (CEM), replacing
- To connect the breakout box, see Connecting the breakout box
- For information about signals, see Signal specification
- See Checking wiring and terminals .
Were any faults found?
- YES
Refer to Verification
- NO
Refer to Checking Overtemperature