Checking wiring and connectors
Check the control module and fuel level sensor connectors. Check for contact resistance and oxidation. Check for loose connections.
Check the cables between fuel level sensor connector terminal #7 and control module terminal #A08 (#A8). Check for an intermittent short-circuit to ground. Check for an intermittent open-circuit. Check for an intermittent short-circuit to supply voltage.
Check the ground lead between control module terminal #A10 (#A10) and fuel level sensor connector terminal #6. Check for an intermittent open-circuit.
Check the cables between the left and right fuel level sensors. Check for an intermittent open-circuit. Check the terminal pins and connectors. Check for loose connections. Check for contact resistance and oxidation.
Other information:
- For further information about signals and other values, see Signal specification
- To connect the breakout box, see Connecting the breakout box
- To access the control module, see Integrated relay/fuse box cargo compartment/rear electronic module, replacing
- To access the fuel level sensors, see Left fuel gauge sensor and Right side fuel pump with level sensor
- See Checking wiring and terminals. Intermittent faults .
- Continue
Refer to Information