Checking the control module for open-circuits
- Ignition off
- Remove relay 2/113
- Ignition on.
Check the driver circuit for the relay coil for an intermittent open-circuit as follows: activate the relay driver. Measure the voltage between terminals #1 and #2 on the relay base.
HINT: The voltage between terminals #1 and #2 should be battery voltage.
HINT: If the value deviates excessively, check the voltage between terminal #2 and the battery and between terminal #1 and ground. Both should equal battery voltage.
HINT: Do not forget to check that the power supply to the control module is OK.
Other information:
- To access the integrated relay / fusebox in the cargo compartment, see Integrated relay/fuse box cargo compartment/rear electronic module, replacing
- See Checking wiring and terminals. Intermittent faults .
Was a fault detected?
- YES
OKAY: Troubleshooting has been completed.
- NO