Checking For A Short-Circuit
Check the cable between the sun roof module (SRM) and the roof lamp module. Check for a short-circuit to supply voltage.
UEM-0070 Sun roof. Faulty signal
The sun roof module (SRM) terminal #3A and roof lamp module terminal #2B.
UEM-0070 Sun roof. Faulty signal
The sun roof module (SRM) terminal #7A and roof lamp module terminal #1B.
Replace the cable if a fault is found.
Other information:
- For further information about signals and other values, see Signal Specification
- To access the roof lamp module connector, see Interior Lighting, Replacing
- To access the sun roof module (SRM) connector, see Control Module, Sun Roof, Replacing
- See Checking Wiring And Terminals .
- Continue
Refer to Checking the Cable