Checking Control Module For Open-Circuits
Remove relay 2/119.
Check the driver circuit for the relay coil for an intermittent open-circuit as follows:
Measure the voltage between terminals #1 and #2 on the relay base.
See Checking wiring and terminals. Intermittent faults
Activate the relay driver for the right rear window down: Click on the VCT2000 symbol.
HINT: The voltage between terminals #1 and #2 should be battery voltage.
If the value deviates significantly, check voltage between #2 and battery voltage as well as between #1 and ground. Both shall be equal to battery voltage. Check for an intermittent open-circuit. Checking wiring and terminals. Intermittent faults Do not forget to check that the power supply to the control module is OK.
Other information
- Continue
Refer to Information