Checking Control Module For Open-Circuits
Remove relay 2/120.
Check the driver circuit for the relay coil for an open-circuit as follows:
Measure the voltage between the points #1 and #2 in the relay socket. For more information about open circuits, see:Checking wiring and terminals. Permanent fault
Activate the relay with the switch child safety lock, for windows rear doors, on the driver's control panel (activated relay LED on).
HINT: Voltage between #1 and #2 shall be battery voltage.
If the value deviates significantly, check voltage between #2 and battery voltage as well as between #1 and ground. Both shall be equal to battery voltage. Check for open circuits. Refer to: Checking wiring and terminals. Permanent fault
Do not forget to check that the power supply to the control module is OK.
Other information
- Continue
Refer to Information