Checking components and wiring
CAUTION:
Do not apply rust solvent spray or grease to the heated oxygen sensor (HO2S) connector.
Check the signal cable (+) between heated oxygen sensor (HO2S) terminal #4 and control module terminal #A61 (#B1). Check the signal cable (-) between heated oxygen sensor (HO2S) terminal #3 and control module terminal #A62 (#B2). Check for a short-circuit to supply voltage.
HINT: Use a test lamp with at least a 3 W bulb to determine whether the cable is short-circuited to supply voltage.
Try a new heated oxygen sensor (HO2S) if the wiring is OK.
Remedy as necessary.
Other information:
- To connect the breakout box / access the control module, see Connecting the breakout box
- To access or replace the heated oxygen sensor (HO2S), see Heated oxygen sensor (HO2S), replacing
- For information about signals, see ELECTRICAL SYSTEM
- See Contents .
- Continue
Refer to Verification