Checking The Wiring And Component
Check the cable between control module terminal #A45 and knock sensor (KS) terminal 3. Check for a short-circuit to ground.
Check the cable between control module terminal #A64 and knock sensor (KS) terminal 4. Check for a short-circuit to ground.
Remedy as necessary.
Other information:
- To localize the knock sensor (KS), see Location of components
- To connect the breakout box, see Connecting the breakout box
- For information about signals, see Signal specification
- See Checking wiring and terminals
Was a fault found in the wiring?
- YES
Refer to Verification
- NO
Refer to Replacing knock sensor