LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volvo >> 2007 >> S60 Base, AWD >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Transmission - Specifications, Electrical/Electronic >> Specifications, Transmission Control Module (TCM) (B5254T4, TF-80SC AWD; 2006-2007) >> Component Resistance Values >> Linear Pressure Solenoid SLT, SLS/Lock-Up Solenoid SLU
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Linear Pressure Solenoid SLT, SLS/Lock-Up Solenoid SLU

Fig 1: Identifying Ohms Resistance Temperature Graph
GLL141942Courtesy of VOLVO CARS OF NORTH AMERICA.
Component  Remarks  Resistance (Ω) 
Lock-up solenoid (SLU)
Linear pressure solenoid (SLT) (SLS)
Resistance between the solenoid pins +20 °C= 5.0-5.6 Ω

For other values, see diagram. When taking readings at temperatures other than +20 °C, a control reading must be taken at +20 °C. This is done to check whether the resistance is correct or not.