Diagnostic trouble code information
Condition
If the control unit registers signal missing from solenoid P position lock, diagnostic trouble code TCM-0091 will be set.
Substitute Value
- Gear selector blocked.
Possible Source
- Contact resistance in the connectors.
- Open circuit in signal wire or ground wire
Fault symptom[s]
- Orange general warning lamp is on.
- Malfunction indicator light (MIL) is on.
- The gear selector cannot be moved.