Checking the power supply and ground terminals
Check the ABS control module connector for, see Contact resistance and oxidation .
Check fuse 11/9 in the fusebox in the passenger compartment.
NOTE:
If the fuse is blown, check the circuit after the fuse for a short-circuit to ground before replacing the fuse. Then replace the fuse.
Check the power supply cable between fuse 11/9 and the control module for an open-circuit according to Open-circuit, permanent faults .
Also check the wiring between control module terminals #A8 and #A24 and ground terminal 31/95. Check for, see Contact resistance and oxidation . Check for an open-circuit according to Open-circuit, permanent faults .
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the ABS breakout box
- For information about signals, see Signal specification, ABS control module .
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking connectors