Fig 1: Identifying Terminating Resistors
GLL160011Courtesy of VOLVO CARS OF NORTH AMERICA.

A = Master node

B = Slave node

C = Transmitter/receiver

LIN is terminated to the battery voltage on each node via a pull-up resistance

The master node is terminated with 1 kΩ and the slave nodes with 30 kΩ.

The termination resistance forms a parallel circuit and the resistance to the battery voltage depends on the number of connected nodes. The resistance to ground should be infinite or at least extremely large if no communications are in progress.