Evaporator Temperature Sensor 7/41: Check
Prerequisites (unless otherwise specified):
- Breakout box connected.
- Sensor connected.
- Ignition switch position 0.
Check 1
Evaporator temperature sensor:
Measure resistance between terminals #29 and #38 on the breakout box. The value should follow the information below:
R = 3.44 kΩ at 20 °C.
R = 1.47 kΩ at 40 °C.
R = 336 Ω at 80 °C.
R = 187 Ω at 100 °C.
Prerequisites (unless otherwise specified):
- Breakout box connected.
- Sensor connected.
- Ignition switch position 0.
Check 1
Passenger compartment temperature sensor:
Measure resistance between terminals #30 and #38 on the breakout box. The value should follow the information below:
R = 12.98 kΩ at 18 °C.
R = 12.47 kΩ at 19 °C.
R = 11.99 kΩ at 20 °C.
R = 11.53 kΩ at 21 °C.
R = 11.09 kΩ at 22 °C.
R = 10.67 kΩ at 23 °C.