Checking The Component
If the fault is intermittent, it has been registered previously but is no longer present. Intermittent faults can occur for a number of different reasons. The fault is evaluated depending on how it occurs.
Check the connector. Check for contact resistance and oxidation.
Check the signal cable between control module terminal #B8 (#28) and door mirror terminal #8. Check for an open-circuit.
Replace the signal cable if a fault is found.
Try replacing the door mirror if no fault is found.
Remedy as necessary.
Other information:
- Continue
Refer to VERIFICATION